This image represents a sample of raw MDF approximately 600mm wide. Colours displayed on your screen may differ from those of the actual MDF.
FLAMEBLOCK® FRMDF 12mm, 16mm, 18mm, 25mm
Product: |
FLAMEBLOCK FRMDF 12mm, 16mm, 18mm, 25mm |
About this Product: |
Fire Retardant all the way through: In the raw/painted form 12mm and up to 25mm thick, Flameblock is certified to reach Fire Hazard Group 2 for interior walls and ceilings. All Fire Hazard Group Number tests and assessments are done according to AS 5637 using ISO 9705 Room Burn Tests, as required by the National Construction Code (NCC) 2022, Volume 1 - Wall and Ceiling Linings. Please contact us for New Zealand Group Numbers. FLAMEBLOCK is PEFC certified for sustainability. |
Panel sizes: |
2440mmx1220mm, 3050mmx1220mm |
Thickness of Panel(s): |
12mm, 16mm, 18mm, 25mm |
Product Data Sheet: |
Download
|
Availability: |
Good availability ex stock. Please contact us well in advance for very large projects. |
Applications: |
Where Fire Hazard Group 2 is required for raw, painted and veneered FRMDF (noting that only veneers of density up to 755kg/m3 make Group 2 on Flameblock). Note that Flameblock is not moisture resistant. |
About & Applications information: |
Download
|
Origin: |
EU |
Handling and Care instructions |
Download
|
Pressing, Finishing & Fabrication information |
Download
|
Environmental: |
Environmentally certified to be from responsibly managed forests |
Environment Health & Safety information |
Download
|
Available as environmentally certified: |
Yes, specify as PEFC
|
Type of environmental certification: |
PEFC |
PEFC Chain of Custody certificate |
Download
|
Emissions from MDF: |
Formaldehyde E0 |
Formaldehyde certificate |
Download
|
Material Safety Data Sheet |
Download
|
Does not meet Fire Hazard Group 1.
Fire Hazard Group 2 in the raw and painted state, and with with veneers of density up to 755kg/m3 (NCC 2022 / AS 5637 / ISO 9705 Room Burn Test) |
Download FIRE HAZARD GROUP 2 INFORMATION
|
IMPORTANT NOTICE - Briggs Fire Certificate(s)/Report(s) do not apply to FRMDF/veneers/laminates from other suppliers. They apply only to Briggs Veneers' Flameblock FRMDF/veneers/laminates/thicknesses as listed on our Fire Certificate(s)/Report(s). It is the responsibility of the end user to ensure that the products used on their project are as named on these Fire Certificate(s)/Report(s). Briggs Veneers does not accept any responsibility for product substitution by others. Do not publish Briggs Fire Certificate(s)/Report(s) on any website or in product literature as they are the property of Warrington Fire and/or Briggs Veneers. Flameblock is designed and tested to meet the National Construction Code 2019 (NCC 2019) Volume 1, Specification C1.10 Section 4 for interior walls, ceilings and lift car interiors. Flameblock is not rated for use in other areas of buildings that may require fire-retardancy such as doors, around fireplaces, etc. Nor is it rated as “non-combustible”. Panels which have been modified such as with acoustic slotting or multilayered Flameblock are not covered. Briggs Veneers are not qualified to advise what Fire Hazard Group Numbers are required for your application - please seek the advice of a Fire Engineer Consultant or Building Certifier.